Internetska prodaja profesionalne visokotlačne opreme, pribora, specijalnih dodataka i uređaja.
Single electrode for high pressure washers.
Single electrode for high pressure washers.
Temperature controller for devices hot water.
INLET: 3/8" M
LENGTH: 920 mm
PROBE: 8 x 44,5 mm
VOLTAGE: 16 A - 380 V
WORKING RANGE: 0 - 152 °C
Substitute K: 6.685-949.0
Water flow switch Reed for high pressure equipment which protects against water loss.
LENGTH: 83 mm
DIAMETER: 8,9 mm
Substitute K: 2.880-194.0
Electrode double - type block for high pressure washers.
Temperature controller for devices hot water.
INLET: 3/8" M
LENGTH: 1550 mm
PROBE: 8 x 48 mm
VOLTAGE: 16 A - 380 V
WORKING RANGE: 30 - 150 °C
Ignition transformer for high-pressure cleaner with ignition plug 230V.
INPUT VOLTAGE: 230 V
OUTPUT VOLTAGE: 2 x 12 kV
CURRENT: 30 mA
Single electrode for high pressure washers.
Fits to K: HDS 500 C, HDS 550 C, HDS 555, HDS 590C, HDS 600C, HDS 610, HDS 690, HDS 760, HDS 890 ST, HDS 1290 ST, HDS 1000 BE, HDS 1000 DE, HDS 75, HDS 80.
Substitute: 2.880-177.0
Temperature controller for devices hot water.
INLET: M14 M
LENGTH: 1450 mm
PROBE: 6 x 95 mm
VOLTAGE: 15 A - 250 V
WORKING RANGE: 30 - 90 °C
Ignition transformer for high-pressure cleaner with ignition plug 12V.
INPUT VOLTAGE: 12 V
OUTPUT VOLTAGE: 2 x 12000 V
CURRENT: 22 mA
Electrode double - type block for high pressure washers.
Fits to K: HDS 5/11 U, HDS 5/12 C, HDS 5/13 U, HDS 7/12-4M, HDS 10/20-4M, HDS 12/18-4S, HDS 13/20-4S, HDS 500 CI, HDS 501 C, HDS 550 C ECO, HDS 551 C ECO, HDS 555 CI, HDS 558 C, HDS 601 C ECO, HDS 695, HDS 697, HDS 698 C, HDS 1000, HDS 1195, HDS 1195 S ECO, HDS 1295, HDS 2000 SUPER, K 855 H.
Substitute: 2.638-974.0
Temperature controller for devices hot water.
INLET: M14 M
LENGTH: 1550 mm
PROBE: 8 x 50 mm
VOLTAGE: 16 A - 380 V
WORKING RANGE: 0 - 160 °C
Single electrode for high pressure washers.
The cable that transfers the voltage from the transformer to the spark plugs.
Used in pressure washers, mounted in a regulation (bypass) valve or directly in the pump head. Automatically switches off the pump when the pressure increases dangerously.
ACTIVATION PRESSURE: 15 bar
Electrode double - type block for high pressure washers.
Ignition cable for transformers.
Substitute K: 2.638-976.0
Used in pressure washers, mounted in a regulation (bypass) valve or directly in the pump head. Automatically switches off the pump when the pressure increases dangerously.
ACTIVATION PRESSURE: 45 bar
Ignition cable for transformers.
Ignition transformer for high-pressure cleaner with ignition plug 230V.
INPUT VOLTAGE: 230 V
OUTPUT VOLTAGE: 2 x 4000 V
CURRENT: 12 mA
Used in pressure washers, mounted in a regulation (bypass) valve or directly in the pump head. Automatically switches off the pump when the pressure increases dangerously.
ACTIVATION PRESSURE: 25 bar
Ignition cable for transformers.
Ignition transformer for high-pressure cleaner with self- cutting screw 230V.
INPUT VOLTAGE: 230 V
OUTPUT VOLTAGE: 2 x 4000 V
CURRENT: 18 mA
Used in pressure washers, mounted in a regulation (bypass) valve or directly in the pump head. Automatically switches off the pump when the pressure increases dangerously.
ACTIVATION PRESSURE: 45 bar
Ignition cable for transformers.
Ignition transformer for high-pressure cleaner with ignition plug 230V.
INPUT VOLTAGE: 230 V
OUTPUT VOLTAGE: 2 x 5000 V
CURRENT: 20 mA
Used in pressure washers, mounted in a regulation (bypass) valve or directly in the pump head. Automatically switches off the pump when the pressure increases dangerously.
ACTIVATION PRESSURE: 25 bar
Ignition transformer for high-pressure cleaner with self- cutting screw 400V.
INPUT VOLTAGE: 400 V
OUTPUT VOLTAGE: 2 x 4000 V
CURRENT: 18 mA
Fits to K: HDS SUPER, HDS 695, HDS 699, HDS 795, HDS 745, HDS 850, HDS 895, HDS 995, HDS 1195, HDS 1295, HDS 2000 SUPER, HDS 895S, HDS 695S, HDS 1295 M-ECO, HDS 1195 M-ECO, HDS 895 M-ECO.
Used in pressure washers, mounted in a regulation (bypass) valve or directly in the pump head. Automatically switches off the pump when the pressure increases dangerously.
ACTIVATION PRESSURE: 15 bar
Ignition transformer for high-pressure cleaner with ignition plug 400V.
INPUT VOLTAGE: 400 V
OUTPUT VOLTAGE: 2 x 5000 V
CURRENT: 20 mA
Temperature controller for devices hot water.
INLET: 3/8" M
LENGTH: 1520 mm
PROBE: 8 x 44,5 mm
VOLTAGE: 16 A - 380 V
WORKING RANGE: 30 - 150 °C
Substitute K: 6.685-868.0
Ignition cable for transformers.
Ignition transformer for high-pressure cleaner with ignition plug 400V.
INPUT VOLTAGE: 400 V
OUTPUT VOLTAGE: 2 x 4000 V
CURRENT: 12 mA
Ignition transformer for high-pressure cleaner with ignition plug 230V.
INPUT VOLTAGE: 230 V
OUTPUT VOLTAGE: 2 x 12 kV
CURRENT: 30 mA
The protection switch is applied to protect the system fron overloading, if an overlarge current occurs, the switch component will react to cut the system power off.
Fits to K: 7/18c, 7/18 4M, 790, 820, 855, 890, 895S, 1090, 1094, 1050, SUPER, 895S, 695M Eco, 895M Eco, 1195M Eco, 1295M Eco, 798c, 797ci, 995.
Substitute: 6.631-190.0
Ignition cable for transformers.
Switches the pump off automatically if the flow is insufficient.
INLET: 3/8†F
OUTLET: 3/8†F
PRESSURE: max. 390 bar
FLOW: max. 30 l/min
VOLTAGE: max. 250V
CURRENT: max. 3A
FLUID TEMPERATURE: 80 °C
CABLE LENGTH: 1570 mm
RATED PRESSURE - 640 bar
PERMISSIBLE PRESSURE - 700 bar
RATED FLOW - 30 l/min
MAX VOLTAGE - 250 V
MAX CURRENT - 3 A
MAX SWITCHING POWER - 120 VA
MAX FLUID TEMPERATURE - 80 °C
MAX ENVIRONMENT TEMPERATURE - 75 °C
CABLE LENGTH - 1570 mm
VERTICAL POSITION – 4 l/min
Water flow switch Reed for high pressure equipment which protects against water loss.
LENGTH: 75 mm
DIAMETER: 8,0 mm
Position number 9.
INLET: 3/8†M
OUTLET: 3/8†M
OUTLET FOR MANOMETER: 1/4†F
PRESSURE: max. 310 bar
FLOW: max. 30 l/min
VOLTAGE: max. 250V
CURRENT: max. 3A
FLUID TEMPERATURE: 80 °C
CABLE LENGTH: 1570 mm
RATED PRESSURE - 640 bar
PERMISSIBLE PRESSURE - 700 bar
RATED FLOW - 30 l/min
MAX VOLTAGE - 250 V
MAX CURRENT - 3 A
MAX SWITCHING POWER - 120 VA
MAX FLUID TEMPERATURE - 80 °C
MAX ENVIRONMENT TEMPERATURE - 75 °C
CABLE LENGTH - 1570 mm
VERTICAL POSITION – 4 l/min
HORIZONTAL POSITION – 3 l/min
Internetska prodaja profesionalne visokotlačne opreme, pribora, specijalnih dodataka i uređaja.